Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/185
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBelan, Peterson Adriano-
dc.creator.Latteshttp://lattes.cnpq.br/8197537484347198por
dc.contributor.advisor1Librantz, Andre Felipe Henriques-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3569470521730110por
dc.contributor.advisor-co1Araújo, Sidnei Alves de-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/2542529753132844por
dc.date.accessioned2015-04-07T21:10:34Z-
dc.date.available2013-05-14-
dc.date.issued2012-08-13-
dc.identifier.citationBELAN, Peterson Adriano. Técnicas de visão computacional aplicadas na automação de processos metrológicos. 2012. 150 f. Dissertação (Mestrado em Engenharia) - Universidade Nove de Julho, São Paulo, 2012.por
dc.identifier.urihttp://bibliotecatede.uninove.br/tede/handle/tede/185-
dc.description.resumoUm problema comum encontrado nos laboratórios de calibração é a confiabilidade dos resultados obtidos na calibração de instrumentos de medição, especialmente quando eles não possuem interface de comunicação. Neste caso o consumo de tempo e os erros humanos cometidos são problemas enfrentados por vários desses laboratórios. Neste contexto, muitas abordagens baseadas em visão de computador têm sido propostas na literatura para automatizar processos de calibração. Desta forma, neste trabalho foram propostas quatro abordagens de visão computacional para a área de metrologia, sendo três delas visando a calibração de instrumentos e uma visando a inspeção da qualidade de moldes para injeção de plástico. O primeiro algoritmo é baseado em correlação cruzada normalizada para leitura de dígitos do display de manômetro digital, o segundo utiliza projeções radiais juntamente com algoritmo de Bresenham para determinar a posição do ponteiro em relógios comparadores analógicos, o terceiro efetua a segmentação da imagem para determinar o tamanho dos furos de peneiras grano-volumétrica. Por fim o quarto algoritmo envolve a automatização do processo de inspeção de moldes para injeção de plástico por meio de um equipamento laser para ajudar a detectar problemas, tais como excesso de polimento ("casca de laranja") ou riscos. Os resultados experimentais mostraram que os quatro algoritmos propostos apresentaram boa precisão e bom desempenho de processamento, tornando-se assim viáveis para as tarefas metrológicas sugeridas.por
dc.description.abstractA common problem found in the calibration laboratories is the reliability of the results obtained in calibration of instruments, especially when they do not have a built-in communication interface. In this case, the spending time is increased significantly and the calibration can be subject to human error. In this context, many approaches based on computer vision have been proposed in the literature for automating calibration processes. Thus, four approaches of computer vision for application to the area of metrology were proposed in this work, three of them aiming at the calibration of instruments and one at the evaluation of quality injection mould surface. The first algorithm is based on normalized cross-correlation for reading digits of the display of a digital manometer; the second uses radial projections with Bresenham algorithm to determine the position of the pointer in analogical dial gages; the third makes a segmentation of the image to determine the holes size of screens grano-volumetric; and finally the fourth algorithm involves the automation of the evaluation of injection mould surface in which the proposed algorithm applied to images generated by means of laser device could help to detect problems such as over-polishing ("orange peel") or risks. Results showed that the proposed algorithms presented high accuracy and performance and can be used in real time systems applied to calibration processes.eng
dc.description.provenanceMade available in DSpace on 2015-04-07T21:10:34Z (GMT). No. of bitstreams: 1 B_Peterson Adriano Belan.pdf: 16675674 bytes, checksum: 099a12de56c8f838dfe0f652d71a4727 (MD5) Previous issue date: 2012-08-13eng
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Nove de Julhopor
dc.publisher.departmentEngenhariapor
dc.publisher.countryBRpor
dc.publisher.initialsUninovepor
dc.publisher.programPrograma de Pós-Graduação de Mestrado e Doutorado em Engenharia de Produçãopor
dc.rightsAcesso Abertopor
dc.subjectVisão computacionalpor
dc.subjectcalibraçãopor
dc.subjectinstrumentos de mediçãopor
dc.subjectcorrelação cruzada normalizadapor
dc.subjectprojeção radialpor
dc.subjectGaborpor
dc.subjectmolde de injeçãopor
dc.subjectComputer visioneng
dc.subjectcalibrationeng
dc.subjectmeasurement instrumentseng
dc.subjectnormalized crosscorrelationeng
dc.subjectradial projectioneng
dc.subjectGaboreng
dc.subjectinjection mouldeng
dc.subject.cnpqENGENHARIAS::ENGENHARIA DE PRODUCAOpor
dc.titleTécnicas de visão computacional aplicadas na automação de processos metrológicospor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação de Mestrado e Doutorado em Engenharia de Produção

Arquivos associados a este item:
Arquivo TamanhoFormato 
B_Peterson Adriano Belan.pdf16,28 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.