Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/2312
Tipo do documento: Dissertação
Título: Viabilidade e validação do Play (Pediatric Living Activity in Youth) teste para avaliar a capacidade funcional em crianças e adolescentes
Título(s) alternativo(s): Feasibility and validation of the Play (Pediatric Living Activity in Youth) test to assess functional capacity in children and adolescents
Autor: Santos, Jenifer dos
Primeiro orientador: Lanza, Fernanda de Cordoba
Primeiro coorientador: Corso, Simone Dal
Primeiro membro da banca: Lanza, Fernanda de Cordoba
Segundo membro da banca: Dias, Raphael Mendes Ritti
Terceiro membro da banca: Chiavegato, Luciana Dias
Resumo: Introdução: Crianças e adolescentes com doença pulmonar crônica podem ter capacidade funcional reduzida. Existem instrumentos de avaliação que mimetizam as AVD como o TGlittreP, entretanto este não abrange as atividades do cotidiano infantil, como brincadeiras que incluem a corrida e atividades esportivas coletivas. Portanto, há necessidade de instrumento de avaliação composto por atividades funcionais de criança/adolescente. Objetivo: Estudar a viabilidade e validar o PLAY (pediatric living activity in youth) teste em crianças e adolescentes asmáticos. Métodos: Estudo transversal realizado com crianças e adolescentes com idade entre 6 e 17 anos. Para a viabilidade foram realizadas as seguintes avaliações: espirometria, teste de exercício cardiopulmonar (TECP), e 10 AVD propostas. Para a validação foi utilizada a Espirometria, TGlittre-P, STM, TECP e PLAY teste. Resultados: Viabilidade: Dentre as 10 AVD, Lançar bola (VE: 16,8 (14,1-20,7L/min), VO2: 14,9 (12,1-16,9mL/Kg), FC: 104 (101-126bpm)), e subir rampa (VE: 14,2 (12,7-15,5L/min), VO2: 0,14 (0,10-0,21mL/Kg), FC: 128 (93-136bpm)) apresentaram menores demandas. Validade: Ao comparar o PLAY os demais testes, o PLAY teste apresenta FC menor (15517bpm) que TECP (18814) e STM (18718), p < 0,001, e maior que o TGlittre-P (14718), p = 0,02. O VO2 no PLAY teste foi menor (32,87,5ml/kg) que TECP (42,08,8 ml/kg) e STM (48.914,2 ml/kg), p < 0,001, e maior que no TGlittre-P (27,49,0ml/kg), p = 0,02. PLAY teste e TGlittre-P apresentaram menor VE ao serem comparados ao TECP e STM (p<0,001). Não houve diferença no tempo de execução do PLAY teste e TGlittre-P p > 0,05. Conclusão: O PLAY teste mostrou ser válido e reprodutível para avaliar a capacidade funcional de crianças e adolescentes asmáticos.
Abstract: Introduction: Children and adolescents with chronic lung disease may have reduced functional capacity. There are assessment instruments that mimic ADL as TGlittreP, but are not covered by daily children's activities, such as earrings that reproduce a race and collective sports activities. Therefore, there is a need for an assessment instrument composed of functional activities of children / adolescents. Objective: To study the feasibility and validate the PLAY (pediatric living activity in youth) test in children and adolescents with asthma. Methods: Cross-sectional study conducted with children and adolescents aged 6 to 17 years. For viability, the following evaluations were performed: spirometry, cardiopulmonary exercise test (CPET), and 10 proposed ADLs. Spirometry, TGlittre-P, MST, CEPT and PLAY test were used for validation. Results: Viability: Among the 10 ADLs Throwing the ball (VE: 16.8 (14.1-20.7L / min), VO2: 14.9 (12.1-16.9mL / kg), HR: 104 (101-126bpm)) and going up the ramp (VE: 14.2 (12.7-15.5L / min), VO2: 0.14 (0.10-0.21mL/kg), HR: 128 (93-136bpm)) lower demands. Validity: When comparing PLAY to other tests, PLAY test presents HR lower (15517bpm) than CEPT (18814) and MST (18718), p <0.001, and higher than TGlittre-P (14718), p = 0.02. The VO2 in the PLAY test was lower (32.87.5 ml / kg) than CEPT (42.08.8 ml / kg) and MST (48.914.2 ml / kg), p <0.001, and greater than in TGlittre-P (27.49.0 ml / kg), p = 0.02. PLAY test and TGlittre-P showed lower VE when compared to CEPT and MST (p <0.001). There was no difference in the execution time of the PLAY test and TGlittre-P p> 0.05. Conclusion: The PLAY test proved to be valid and reproducible to assess the functional capacity of children and adolescents with asthma.
Palavras-chave: capacidade funcional
atividade de vida diária
pediatria
estudos de viabilidade
reprodutibilidade dos testes
confiabilidade dos dados
functional capacity
daily life activity
pediatrics
viability studies
reproducibility of tests
data reliability
Área(s) do CNPq: CIENCIAS DA SAUDE
Idioma: por
País: Brasil
Instituição: Universidade Nove de Julho
Sigla da instituição: UNINOVE
Departamento: Saúde
Programa: Programa de Pós-Graduação em Ciências da Reabilitação
Citação: Santos, Jenifer dos. Viabilidade e validação do Play (Pediatric Living Activity in Youth) teste para avaliar a capacidade funcional em crianças e adolescentes. 2020. 79 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo.
Tipo de acesso: Acesso Aberto
URI: http://bibliotecatede.uninove.br/handle/tede/2312
Data de defesa: 20-Fev-2020
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Reabilitação

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
JENIFER DOS SANTOS.pdfJENIFER DOS SANTOS2,5 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.