Título: Reprodutibilidade e validade do teste de Performance Física Funcional de 10 tarefas (PFP-10) em pacientes com doença pulmonar obstrutiva crônica
Título(s) alternativo(s): Reprodutibilidade and validity of the test of Functional Physical Performance of 10 tasks (PFP-10) in patients with pulmonary illness obstrutiva chronicle
Autor: Stanzani, Vera Lúcia Tavares de Souza
Primeiro orientador: Malaguti, Carla
Primeiro coorientador: Corso, Simone Dal
Primeiro membro da banca: Chiavegato, Luciana Dias
Segundo membro da banca: Oliveira, Luis Vicente Franco de
Terceiro membro da banca: Sampaio, Luciana Maria Malosá
Quarto membro da banca: Napolis, Lara Maris
Resumo: Introdução: Pacientes com doença pulmonar obstrutiva crônica (DPOC), frequentemente, são limitados na performance de atividade de vida diária (AVD). Testes avaliação habituais de capacidade funcional podem não representar seu verdadeiro nível funcional, pois avaliam apenas uma única tarefa (p.ex., caminhada). Assim, o teste de capacidade física funcional PFP-10 consiste em um instrumento viável de avaliação das AVD nesta população. Objetivos: Avaliar a reprodutibilidade e validade do teste PFP-10 em pacientes com DPOC. Método: Estudamos 28 pacientes com DPOC e 9 controles saudáveis pareados por idade e gênero. Todos realizaram avaliações antropométrica e espirométrica para a caracterização da amostra. O grupo DPOC realizou também avaliação da dispnéia pela Medical Research Council modificada (MMRC) e o TC-6min para determinar gravidade da doença e respondeu ao questionário London Chest Activity of Daily Living Scale (LCADL). Todos executaram dois testes PFP-10, em dias diferentes e no mesmo período do dia. Resultados: O PFP-10 mostrou elevada concordância entre teste e reteste, (CCI 0,82 a 0,99 no grupo DPOC e 0,73 a 0,99 no grupo controle com p ≤ 0,05), assim como o tempo total do teste e reteste do PFP-10 mostrou excelente reprodutibilidade (CCI: 0,98, p ≤ 0,05), e uma correlação negativa de moderada magnitude entre o tempo total do PFP-10 e TC-6min (r = - 0,44, p = 0,02), assim como uma tendência à correlação do PFP-10 e o escore total do LCADL (r = 0,37, p = 0,06) nos DPOC. Os pacientes com DPOC apresentaram menor capacidade durante a execução da maioria das tarefas avaliadas no teste PFP-10 quando comparados ao grupo controle. Conclusão: O teste PFP-10 mostrou-se altamente reprodutível e válido em pacientes com DPOC, sendo capaz de determinar uma pior performance funcional dos pacientes com DPOC na realização das atividades de vida diária.
Abstract: Introduction: Patients with chronic obstructive pulmonary disease (COPD) frequently present reduced capacity to perform activities of daily living (ADL). However, the tests usually aplicable to assess functional capacity can not represent the true functional level in these patients because they provide only one task, i.e., walking. In this context, the short version: Continuous-Scale Physical Functional Performance test (PFP-10) consists of a tool of evaluation for ADL, which might be useful for assessing this population. Objectives: The objective of this study was to test the reproducibility of PFP-10 in patients with COPD. Method: Twenty-eight patients with COPD, clinically stable, and nine control subjects. All subjects performed anthropometric and spirometric evaluations to characterize the samples. COPD group also performed assessment of dyspnea by Modified Medical Research Council, and six-minute walking test to classify the severity of COPD by BODE index. In addition, patients responded London Chest Activity of Daily Living (LCADL) questionnaire. All subjects performed two PFP-10 tests in two different days, at the same period of the day. Results: It was observed a high reliability in PFP-10 between test and retest, with intraclass correlation coeficient (ICC) from 0.82 to 0.99 for COPD group, and from 0.73 to 0.99 for control group (p ≤ 0.05 for all tasks). The total time to perform PFP-10 in two different days showed excelent reproducibilty (ICC: 0.98; p ≤ 0.05). In COPD group, it was observed a moderate negative correlation between total time to perform PFP-10 and six-minute walking test (r = - 0.44, p = 0.02), and a tendency to significance for PFP-10 and total score of LCADL questionnaire (r = 0.37; p = 0.06). In addition, patients with COPD showed lower capacity during execution of the most tasks evaluated by PFP-10 than control group. Conclusion: PFP-10 is a highly reproducible test and a valid instrument to assess patients with COPD. Comparing to control group, this test was able to determine lower functional performance in patients with COPD during activities of daily living.
Palavras-chave: capacidade funcional
atividade de vida diária
DPOC
functional capacity
activities of daily living
COPD
Área(s) do CNPq: CIENCIAS DA SAUDE
Idioma: por
País: BR
Instituição: Universidade Nove de Julho
Sigla da instituição: UNINOVE
Departamento: Saúde
Programa: Programa de Pós-Graduação em Ciências da Reabilitação
Citação: STANZANI, Vera Lúcia Tavares de Souza. Reprodutibilidade and validity of the test of functional physical performance of 10 tasks (pfp-10) in patients with pulmonary illness obstrutiva chronicle.. 2009. 149 f. Dissertação (Mestrado em Saúde) - Universidade Nove de Julho, São Paulo, 2009.
Tipo de acesso: Acesso Aberto
URI: http://bibliotecatede.uninove.br/tede/handle/tede/819
Data de defesa: 14-Dez-2009
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Reabilitação

Arquivos associados a este item:
Arquivo TamanhoFormato 
B_Vera Lucia Taveira de Souza Stanzani.pdf3,72 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.