Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/1816
Tipo do documento: Dissertação
Título: Shuttle walk teste realizado na esteira e corredor são testes intercambiáveis?
Título(s) alternativo(s): Shuttle walk test performed on the mat and corridor are testing interchangeable?
Autor: Santos, Patricia Lira dos 
Primeiro orientador: Lanza, Fernanda de Cordoba
Primeiro membro da banca: Lanza, Fernanda de Cordoba
Segundo membro da banca: Corso, Simone Dal
Terceiro membro da banca: Malaguti, Carla
Resumo: Introdução: Não está definido na literatura se existe diferença na velocidade atingida no SWTI se for realizado na esteira (SWTI-E) ou corredor (SWTI-C). Objetivos: Comparar a velocidade, distância percorrida e as respostas cardiopulmonares entre SWTI realizado na esteira e no corredor. Método: Trinta e quatro voluntários com DPOC [19 homens; VEF1 50 ± 17 % prev; idade (63 ± 13)], foram submetidos a quatro testes (dois SWTI-C e dois SWTI-E), o teste SWTI-C foi realizado segundo definição original. O SWTI-E foi realizado em uma esteira motorizada, o incremento de velocidade do SWTI-C foi transportado para o ergômetro da esteira. Ambos testes foram realizados duas vezes, em dias diferentes e de forma aleatória. O consumo de oxigênio (VO2pico), produção de gás carbônico (VCO2), ventilação minuto (VE), frequência cardíaca (FC), e saturação de pulso de oxigênio (SpO2) foram medidos continuamente durante os testes. Adicionalmente, Borg Dispneia (Borg D) e Borg fadiga de membros inferiores (Borg MI) foram registrados no início e final dos testes; Resultados: Houve diferença na distância percorrida (SWTI-E 371± 181 vs SWT-C 295 ± 149, p=0,001) e velocidade (SWT-E 3,5km/h vs SWTI- C 3,2km/h, p=0,010). Adicionalmente, o Borg MI, VE/VCO2 e VE/VO2 foram superiores no SWTI-C (p <0,05). Demais variáveis, FC, Borg D, VE, VVM e VCO2, foram similares em ambos testes (p > 0,05). Conclusões: O SWTI realizado na esteira resulta em maior distância percorrida e, consequentemente, maior velocidade atingida. O SWTI realizado na esteira e corredor não são intercambiáveis.
Abstract: Introduction: It is not established at literature whether there is difference of the speed in ISWT carried out on treadmill (ISWTI-T) or corridor. Objective: To compare the speed, walked distance and cardiopulmonary responses between SWTI carried out on treadmill versus corridor. Methods: Thirty four volunteers with COPD [19 mens; 50 ± 17 % prev; age (63 ± 13)], were submitted to four tests (two ISWT-C and two ISWT-T), the ISWT-C was carried out according to original definition. The ISWT-T was carried out on an automatic treadmill, the speed increase of ISWT-C was carried to the ergometer. Both tests were carried out twice, in different days and randomized. The oxygen consumption (VO2peak), carbon dioxide production (VCO2), minute ventilation (MV), cardiac frequency (CF) and pulse oxygen saturation (SpO2) were measured during the tests continuously. Additionally, Borg dyspnea (Borg D) and Borg lower members fatigue (Borg MI) were registered at the beginning and end of the tests.Results: There was difference in walked distance (ISWT-T 371± 181 vs ISWT-C 295 ± 149, p=0,001) and speed (ISWT-T 3,5km/h vs ISWT- C 3,2km/h, p=0,010). Additionally, Borg MI, VE/VCO2 and VE/VO2 were higher in ISWT-C (p<0,05). Others variables, CF, Borg D, MV, MVV and VCO2 , were similar in both tests (p>0,05). Conclusions: The SWTI carried out on treadmill results in more walked distance and consequently, more speed reached. The ISWT treadmill and corridor are not interchangeable.
Palavras-chave: DPOC
capacidade funcional
COPD
functional capacity
Área(s) do CNPq: CIENCIAS DA SAUDE
Idioma: por
País: Brasil
Instituição: Universidade Nove de Julho
Sigla da instituição: UNINOVE
Departamento: Saúde
Programa: Programa de Pós-Graduação em Ciências da Reabilitação
Citação: Santos, Patricia Lira dos. Shuttle walk teste realizado na esteira e corredor são testes intercambiáveis?. 2015. 65 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo.
Tipo de acesso: Acesso Aberto
URI: http://bibliotecatede.uninove.br/handle/tede/1816
Data de defesa: 17-Dez-2015
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Reabilitação

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Patricia Lira dos Santos.pdfPatricia Lira dos Santos1,11 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.