Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/2310
Tipo do documento: Dissertação
Título: Validade e reprodutibilidade do teste de marcha estacionária de dois minutos em pacientes com doença arterial periférica
Título(s) alternativo(s): Validity and reproducibility of the two-minute step in patients with peripheral arterial disease
Autor: Braghieri, Heloisa Amaral 
Primeiro orientador: Dias, Raphael Mendes Ritti
Primeiro coorientador: Correia, Marilia de Almeida
Primeiro membro da banca: Dias, Raphael Mendes Ritti
Segundo membro da banca: Corso, Simone Dal
Terceiro membro da banca: Cucato, Gabriel Grizzo
Resumo: Introdução: Pacientes com doença arterial periférica (DAP) que apresentam claudicação intermitente (CI) evoluem com declínio funcional e limitações para realizar atividades de vida diária. Apesar de existirem testes funcionais específicos para esses pacientes, poucos são aplicáveis em situações práticas, fazendo-se necessário a identificação de testes que possam ser utilizados nessas condições. Objetivo: Analisar a validade e reprodutibilidade do teste de marcha estacionária de dois minutos (TME2) em pacientes com DAP. Métodos: Participaram do estudo 24 pacientes com DAP e sintomas de CI que foram recrutados no ambulatório de Claudicação Intermitente da Universidade Nove de Julho. Os pacientes realizaram o TME2 e o teste de caminhada de seis minutos (TC6M) duas vezes. Antes e após os testes foram obtidas a frequência cardíaca e a pressão arterial. Foi medida a resposta da frequência cardíaca, número de passos até o paciente começar a sentir a dor e o número de passos total do teste. Imediatamente após, foram obtidas a percepção de esforço (Borg); percepção de prazer e desprazer (escala de Hardly e Rejeski), percepção de dor (escala visual analógica de dor - Eva). Resultados: Os coeficientes de correlação intraclasse observados entre os dois TME2 foram superiores a 0,9 para as variáveis de desempenho e para a frequência cardíaca média. Foi observado viés de 0,7 e limites de concordância entre 11,24 e -9,60 e foi observada a presença de um outlier. O desempenho do teste de TME2 foram correlacionados com o TC6M (r= 0,25, p= 0,22). Conclusão: O TME2 apresenta boa reprodutibilidade em pacientes com DAP sintomática. No entanto, o desempenho no TME2 não está correlacionado com o TC6M. Assim, a utilização do TME2 não é um teste acurado para avaliar a capacidade funcional de paciente com DAP e sintomas de claudicação intermitente, não podendo substituir o TC6M.
Abstract: Introduction: Patients with peripheral arterial disease (PAD) who present with intermittent claudication (IC) evolve with functional decline and limitations to perform activities of daily living. Although there are specific functional tests for these patients, few are applicable in practical situations, making it necessary to identify tests that can be used in these conditions. Objective: To analyze the validity and reproducibility of the two-minute step test (2MST) in patients with PAD. Methods: Twenty-four patients with PAD and IC symptoms who were recruited at the Nove de Julho University Intermittent Claudication clinic participated in the study. Patients underwent 2MST and the six-minute walk test (6MWT) twice. Before and after the tests, heart rate and blood pressure were obtained. The heart rate response, number of steps until the patient started to feel the pain and the total number of steps in the test were measured. Immediately after, the perception of effort (Borg) was obtained; perception of pleasure and displeasure (Hardly and Rejeski scale), perception of pain (visual analogue scale of pain - Eva). Results: The intraclass correlation coefficients observed between the two 2MST were higher than 0.9 for the performance variables and for the average heart rate. Bias of 0.7 and limits of agreement between 11.24 and -9.60 were observed and the presence of an outlier was observed. The performance of the 2MST test was correlated with the 6MWT (r = 0.25, p = 0.22). Conclusion: 2MST has good reproducibility in patients with symptomatic PAD. However, performance on 2MST is not correlated with the 6MWT. Thus, the use of 2MST is not an accurate test to assess the functional capacity of patients with PAD and symptoms of intermittent claudication, and cannot replace the 6MWT.
Palavras-chave: doença arterial periférica
capacidade funcional
teste de marcha estacionária de dois minutos
peripheral arterial disease
functional capacity
two-minute step test
Área(s) do CNPq: CIENCIAS DA SAUDE
Idioma: por
País: Brasil
Instituição: Universidade Nove de Julho
Sigla da instituição: UNINOVE
Departamento: Saúde
Programa: Programa de Pós-Graduação em Ciências da Reabilitação
Citação: Braghieri, Heloisa Amaral. Validade e reprodutibilidade do teste de marcha estacionária de dois minutos em pacientes com doença arterial periférica. 2019. 66 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo.
Tipo de acesso: Acesso Aberto
URI: http://bibliotecatede.uninove.br/handle/tede/2310
Data de defesa: 19-Dez-2019
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Reabilitação

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
HELOISA AMARAL BRAGHIERI.pdfHELOISA AMARAL BRAGHIERI1,04 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.