Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/2540
Tipo do documento: Tese
Título: Estudo comparativo da transmissão da luz, impacto térmico e sensibilidade dolorosa em tendão calcâneo de humanos entre três diferentes dispositivos de terapia de fotobiomodulação disponíveis no mercado
Título(s) alternativo(s): Comparative study of light transmission, thermal impact and painful sensitivity between three different photobiomodulation therapy devices available in human tendon
Autor: Melo, Fernando Hess Câmara 
Primeiro orientador: Leal Junior, Ernesto Cesar Pinto
Primeiro membro da banca: Leal Junior, Ernesto Cesar Pinto
Segundo membro da banca: Miranda, Eduardo Foschini
Terceiro membro da banca: Frigo, Lúcio
Resumo: A utilização da Terapia de Fotobiomodulação (TFBM) vem se mostrando favorável no processo de reparação tendínea. Embora vários estudos atestem o efeito benéfico TFBM nas tendinopatias, poucos estudam a penetração da luz in situ, mas sim in vitro e com medidas de penetração imediata. Portanto este estudo visou investigar os perfis de tempo de penetração de três diferentes dispositivos de TFBM no tendão calcâneo humano in situ durante 150 segundos de exposição. Um dispositivo classe 4, com potência média de saída 9000 mW. Um dispositivo Classe 3B, com 100mW de potência média. O terceiro, seria o dispositivo Classe 1M, com 450mW de potência. Para tal, foi realizado um estudo tranversal, no qual foram recrutados 18 voluntários saudáveis. O estudo foi realizado com o tendão em condição relaxada. No ensaio as coletas foram realizadas com o voluntário deitado, os tendões calcâneos (direito e esquerdo) marcados e previamente foi realizada a aquisição de imagens ultrassonográficas para medida da espessura do conjunto pele, tendão e pele, em seguida os voluntários receberam a TFBM. O spot do dispositivo esteve em contato com a pele, na região lateral do tornozelo. A energia penetrante pele a pele foi aferida por um medidor de potência óptica na face medial do tornozelo, após os 150 segundos de irradiação. Os tendões calcâneos direito e esquerdos dos voluntários foram irradiados de maneira sequencial. O mesmo procedimento foi realizado para os três dispositivos de TFBM utilizados no presente estudo, com as especificações orientadas pela empresa responsável por cada dispositivo. Os resultados ofereceram uma diferença alarmante entre os dispositivos quanto à absorção e disponibilidade de energia e sensibilidade dolorosa, secundária ao aquecimento do tecido irradiado.
Abstract: The use of PBMT has been favorable in the tendon repair process. Although several studies attest to the beneficial effect of PBMT on tendinopathies, only a few studies the penetration of light in situ, but in vitro and with immediate penetration measurements. Therefore this study aims to investigate the penetration time profiles of three different PBMT devices in the human Achilles tendon in situ during 150 seconds of exposure. One is a Class 4 device, with a Mean Power Output (MPO) of 9000 mW. The second is a Class 3B, with an MPO of 100mW. The third device is a Class 1M, with an MPO 450mW. To this end, a cross-sectional study was conducted in which 18 healthy volunteers were recruited in order to perform tests, with the tendon in relaxed condition. In the trial the collections were performed with the volunteer lying down, the Achilles tendons (right and left) previously marked and with the ultrasound images already acquired to measure the thickness of the skin, tendon and skin joint, thereafter the volunteers received the PBMT. The spot of the device will be in contact with the skin, in the lateral region of the ankle. Penetrating energy skin to skin was measured by an optical power meter on the medial face of the ankle after 150 seconds of irradiation. The right and left Achilles tendons of the volunteers were irradiated sequentially. The same procedure was performed for the three devices, with proper specifications offered by the manufacturer. The results offered a warning difference between the devices in energy absorption, availability and painful feel, prior to the heat on the skin tissue irradiated.
Palavras-chave: laser
LED (Light Emitting Diode)
Terapia de Fotobiomodulação (TFBM)
penetração
tendão calcâneo
low-level laser therapy
LED (Light Emitting Diode)
Photobiomodulation Therapy (PBMT)
penetration
achilles tendon
Área(s) do CNPq: CIENCIAS DA SAUDE
Idioma: por
País: Brasil
Instituição: Universidade Nove de Julho
Sigla da instituição: UNINOVE
Departamento: Saúde
Programa: Programa de Pós-Graduação em Ciências da Reabilitação
Citação: Melo, Fernando Hess Câmara. Estudo comparativo da transmissão da luz, impacto térmico e sensibilidade dolorosa em tendão calcâneo de humanos entre três diferentes dispositivos de terapia de fotobiomodulação disponíveis no mercado. 2020. 64 f. Tese( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo.
Tipo de acesso: Acesso Aberto
URI: http://bibliotecatede.uninove.br/handle/tede/2540
Data de defesa: 9-Dez-2020
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Reabilitação

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Fernando Hess Câmara Melo.pdfFernando Hess Câmara Melo5,77 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.