Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://bibliotecatede.uninove.br/handle/tede/3272
Tipo do documento: | Dissertação |
Título: | Reprodutibilidade da pressão arterial, rigidez arterial e modulação autonômica cardíaca em pacientes com doença de Parkinson |
Título(s) alternativo(s): | Reproducibility of blood pressure, arterial stiffness and cardiac autonomic modulation in patients with Parkinson's disease |
Autor: | Lima, Verônica de Fátima Souza |
Primeiro orientador: | Dias, Raphael Mendes Ritti |
Primeiro membro da banca: | Dias, Raphael Mendes Ritti |
Segundo membro da banca: | Silva, Soraia Micaela |
Terceiro membro da banca: | Batista, Carla da Silva |
Resumo: | A doença de Parkinson (DP) é uma doença neurodegenerativa e apresenta alterações não motoras como as cardiovasculares. A reprodutibilidade das medidas cardiovasculares em DP ainda não foi investigada. Dessa forma, verificamos a reprodutibilidade da pressão arterial (PA) e da modulação autonômica cardíaca (MAC) em pacientes com DP. Para tanto, 20 pacientes, sexo masculino, com DP (65±7 anos), foram avaliados em três visitas. O erro sistemático foi obtido pela ANOVA de medidas repetidas, a confiabilidade pelo coeficiente de correlação intraclasse (CCI) e a concordância pelos limites de concordância de Bland-Altman. P<0,05 foi considerado significativo. A diferença mínima detectável foi calculada. Foram obtidas a frequência cardíaca (monitor Polar V800), a pressão arterial braquial e central (método auscultatório e análise da onda de pulso), a MAC (variabilidade da frequência cardíaca) e a rigidez arterial (velocidade da onda de pulso). Houve erro sistemático na medida da visita 1 comparada à visita 2 (122±3 vs 116±4, p<0,05) da PA sistólica braquial e aórtica. O CCI variou de 0,89 a 0,92 (para as PA aórtica e braquial), as médias das diferenças e os limites de concordância de Bland-Altman foram menores na comparação das visitas 2 e 3. Em relação à MAC e rigidez arterial houve maior variação de medidas com baixa confiabilidade. Em relação à VOP houve um CCI 0,89. Em conclusão, PA braquial e aórtica parecem representar uma medida reprodutível do repouso em homens com DP e as demais medidas, neste estudo, apresentaram grande variação de medidas, com dados menos reprodutíveis. Palavras-chave: doença de Parkinson; sistema cardiovascular; variabilidade da frequência cardíaca; rigidez arterial; reprodutibilidade. |
Abstract: | Parkinson's disease (PD) is a neurodegenerative disease and presents non-motor alterations such as cardiovascular ones. The reproducibility of cardiovascular measurements in PD has not yet been investigated. Thus, we verified the reproducibility of blood pressure (BP) and cardiac autonomic modulation (MAC) in patients with PD. For this purpose, 20 male patients with PD (65±7 years old) were evaluated in three visits. Systematic error was obtained by 1way ANOVA, reliability by intraclass correlation coefficient (ICC) and agreement by BlandAltman limits of agreement. P<0.05 was considered significant. The minimum detectable difference was calculated. Heart rate (Polar V800 monitor), brachial and central blood pressure (auscultatory method and pulse wave analysis), MAC (heart rate variability) and arterial stiffness (pulse wave velocity) were obtained. There was a systematic error in the measurement of visit 1 compared to visit 2 (122±3 vs 116±4, p<0.05) of brachial and aortic systolic BP. The ICC ranged from 0.89 to 0.92 (for aortic and brachial BP), mean differences and Bland-Altman limits of agreement were lower when comparing visits 2 and 3. Regarding MAC and arterial stiffness there was a greater variation of measurements with low reliability. Regarding PWV, there was an ICC of 0.89. In conclusion, brachial and aortic BP seem to represent a reproducible measurement at rest in men with PD and the other measurements, in this study, showed a wide range of measurements, with less reproducible data. |
Palavras-chave: | doença de Parkinson sistema cardiovascular variabilidade da frequência cardíaca rigidez arterial reprodutibilidade Parkinson's disease cardiovascular system heart rate variability arterial stiffness reproducibility |
Área(s) do CNPq: | CIENCIAS DA SAUDE |
Idioma: | por |
País: | Brasil |
Instituição: | Universidade Nove de Julho |
Sigla da instituição: | UNINOVE |
Departamento: | Saúde |
Programa: | Programa de Pós-Graduação em Ciências da Reabilitação |
Citação: | Lima, Verônica de Fátima Souza. Reprodutibilidade da pressão arterial, rigidez arterial e modulação autonômica cardíaca em pacientes com doença de Parkinson. 2023. 61 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo. |
Tipo de acesso: | Acesso Aberto |
URI: | http://bibliotecatede.uninove.br/handle/tede/3272 |
Data de defesa: | 19-Jun-2023 |
Aparece nas coleções: | Programa de Pós-Graduação em Ciências da Reabilitação |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Verônica de Fátima Souza Lima.pdf | Verônica de Fátima Souza Lima | 931,36 kB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.