Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/1133
Registro completo de metadados
Campo DCValorIdioma
dc.creatorGuiselini, Monalisa Jacob-
dc.contributor.advisor1Fernandes, Kristianne Porta Santos-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/6532810307204867por
dc.contributor.advisor-co1Deana, Alessandro Melo-
dc.contributor.referee1Carvalho, Flávio Aimbire Soares de-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/8216583445045638por
dc.contributor.referee2Ferrari, Raquel Agnelli Mesquita-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/7048141683554943por
dc.date.accessioned2015-07-20T18:13:17Z-
dc.date.issued2013-12-19-
dc.identifier.citationGuiselini, Monalisa Jacob. Avaliação das propriedades ópticas dos ossos maxilares e mandibulares humanos. 2013. 53 f. Dissertação( Programa de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúde) - Universidade Nove de Julho, São Paulo .por
dc.identifier.urihttp://bibliotecatede.uninove.br/handle/tede/1133-
dc.description.resumoEste estudo avaliou a interação entre o LBI e os ossos maxilares e mandibulares humanos, no que concerne a transmissão efetiva na aplicação vestíbulo-lingual, espalhamento, atenuação e profundidade de penetração para aplicação cervico-apical. A avaliação da transmissão efetiva do LBI nos ossos alveolares de maxilas e mandíbulas humanas foi realizada com um laser infravermelho e um vermelho. A ponteira do laser foi posicionada na parede óssea oposta ao sensor do medidor de potência, para medir a potência remanescente após passagem pelo osso. Foram realizadas 10 medições com cada laser em cada ponto irradiado (regiões anterior, média e posterior), os dados foram testados estatisticamente. Para avaliar a atenuação, espalhamento e a penetração do laser, as mesmas peças anatômicas foram irradiadas por um laser HeNe posicionado paralelamente à superfície óssea, enquanto uma câmera fotográfica de alta resolução captava as imagens do espalhamento da luz. As imagens foram processadas com auxílio de um software gráfico. Para a aplicação vestíbulo-lingual, na região anterior houve maior transmissão quando comparada com a posterior em ambos os lasers e ossos. O laser de 780 nm evidenciou maior transmissão em todas as regiões analisadas nos 2 ossos. Na aplicação cervico-apical, houve maior atenuação da luz na região anterior tanto na maxila como na mandíbula. As diferenças de comportamento da luz podem estar relacionadas às diferenças anatômicas e fisiopatológicas dos ossos e indicam que pode haver necessidade de ajustar parâmetros dosimétricos a fim de que obter os melhores resultados terapêuticos.por
dc.description.abstractThe present study evaluated the interaction between the low level laser and the human maxillary and mandibular bones, regarding the effective transmission in the buccal-lingual application, scattering, attenuation and penetration depth for cervico-apical application. The evaluation of the effective transmission of the LLL through the maxilla and mandible alveolar bone was performed with a red and infrared lasers. The laser head was positioned on the bone wall opposite to the radiated wall for the measure of the remaining energy passing through the bone tissue. 10 measurements were performed with each laser irradiated at each point, the data were statistically tested. To evaluate the attenuation, scattering, and penetration deph of the laser, the same specimens were irradiated by a He-Ne laser positioned parallel to the bone surface, while a high-resolution camera captured the images of the light scattering. These images were processed with a graphic software. For buccal-lingual application, there was a higher transmission in the anterior region compared to the posterior one on both lasers and bones. The 780 nm laser demonstrated a greater transmission over all analyzed regions on both bones. In the cervico-apical application, a greater attenuation of light occurred on both the anterior maxilla and mandible. The differences on light behavior can be related to the anatomical and pathophysiological differences of bone and indicate that it may be needed to adjust the dosimetric parameters in order to obtain the best therapeutic results.eng
dc.description.provenanceSubmitted by Nadir Basilio (nadirsb@uninove.br) on 2015-07-20T18:13:17Z No. of bitstreams: 1 Monalisa Jacob Guisilini.pdf: 1712688 bytes, checksum: 6f76ee9395201b1b37fc78e5d2eb5168 (MD5)eng
dc.description.provenanceMade available in DSpace on 2015-07-20T18:13:17Z (GMT). No. of bitstreams: 1 Monalisa Jacob Guisilini.pdf: 1712688 bytes, checksum: 6f76ee9395201b1b37fc78e5d2eb5168 (MD5) Previous issue date: 2013-12-19eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Nove de Julhopor
dc.publisher.departmentSaúdepor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNINOVEpor
dc.publisher.programPrograma de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúdepor
dc.rightsAcesso Restritopor
dc.subjecttransmissão efetivapor
dc.subjectespalhamentopor
dc.subjectlaserterapiapor
dc.subjectosso alveolarpor
dc.subjectdosimetriapor
dc.subjecteffective transmissioneng
dc.subjectscatteringeng
dc.subjectlaser treatmenteng
dc.subjectalveolar bone dosimetryeng
dc.subject.cnpqCIENCIAS DA SAUDEpor
dc.titleAvaliação das propriedades ópticas dos ossos maxilares e mandibulares humanospor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúde

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Monalisa Jacob Guisilini.pdfMonalisa Jacob Guiselini1,67 MBAdobe PDFBaixar/Abrir Pré-Visualizar    Solictar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.