Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/1139
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSouza, Ana Maria de-
dc.contributor.advisor1Oliveira, Marcelo Tavares de-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0262402232086674por
dc.contributor.advisor-co1Deana, Alessandro Melo-
dc.contributor.referee1Aguiar, Flávio Henrique Baggio-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/5670826978849599por
dc.contributor.referee2Bussadori, Sandra Kalil-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/4110914499694913por
dc.date.accessioned2015-07-21T15:07:51Z-
dc.date.issued2013-12-10-
dc.identifier.citationSouza, Ana Maria de. Efeito de diferentes doses de energia de unidades LED uni- e multi-ondas nas propriedades mecânicas de resinas compostas. 2013. 36 f. Dissertação( Programa de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúde) - Universidade Nove de Julho, São Paulo .por
dc.identifier.urihttp://bibliotecatede.uninove.br/handle/tede/1139-
dc.description.resumoO objetivo do presente estudo foi avaliar a influência de diferentes doses de energia e unidades LED fotoativadoras de banda estreita e com amplo espectro nas propriedades mecânicas de resinas compostas. Para isso, 6 grupos experimentais foram estabelecidos para cada resina avaliada (IPS Empress Direct – Ivoclar Vivadent, Venus – Heraeus-Kulzer, SDR - Dentsply), de acordo com as diferentes doses de energia (5J; 10J e 20J) e unidades fotoativadoras (Bluephase 16i e Bluephase G2 – Ivoclar Vivadent). Trinta e seis corpos-de-prova foram confeccionados (7mm comprimento X 2mm largura X 1mm de altura) a partir de matrizes de silicone e foram utilizados para avaliação das propriedades mecânicas (resistência à flexão e módulo de elasticidade) utilizando o teste de flexão de três pontos, em máquina de ensaio universal a uma velocidade de 0,5 mm/min até que ocorresse a fratura do corpo-de-prova. Os dados foram avaliados quanto à sua normalidade e então, aplicado a Análise de Variância a dois critérios e teste de Tukey, com nível de significância fixado em 5%. Os resultados mostraram que as resinas apresentaram comportamentos diferentes entre si tanto pelas doses de energia utilizadas quanto pela diferença dos espectros de luz emitidos pelas diferentes fontes. Conclui-se dos dados apresentados que os fatores estudados neste trabalho têm relação direta com as propriedades mecânicas dos compósitos resinosos.por
dc.description.abstractThe aim of the present study was to evaluate the influence of different doses of energy and uni- or multi-wave LED units on mechanical properties of composite resins. Thereunto, six experimental groups were established for each assessed resin (IPS Empress Direct - Ivoclar Vivadent , Venus - Heraeus - Kulzer , SDR - Dentsply) according to the different different amounts of energy (5J , 10J and 20J) and LED unit (bluephase 16i and bluephase G2 - Ivoclar Vivadent) . Thirty six specimens were prepared (7mm long x 2mm wide x 1mm height) from silicon matrices and were used for evaluation of mechanical properties (flexural strength and modulus of elasticity) using the three points bending test, in a universal testing machine at a speed of 0.5 mm/min until the specimens fracture. Data were tested for normality and then the two-way analysis of variance was applied and Tukey's test was used to point out differences among means, with significance level set at 5%. Thus, the results showed that the resins presented different performance by energy amounts and by the difference of the spectra of light emitted by different sources. It appears from the data presented that the factors studied in this work are directly related to the mechanical properties of resin composites.eng
dc.description.provenanceSubmitted by Nadir Basilio (nadirsb@uninove.br) on 2015-07-21T15:07:51Z No. of bitstreams: 1 Ana Maria de Souza.pdf: 717565 bytes, checksum: 0b6ad0f4adba71695d0147808fdc405c (MD5)eng
dc.description.provenanceMade available in DSpace on 2015-07-21T15:07:51Z (GMT). No. of bitstreams: 1 Ana Maria de Souza.pdf: 717565 bytes, checksum: 0b6ad0f4adba71695d0147808fdc405c (MD5) Previous issue date: 2013-12-10eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Nove de Julhopor
dc.publisher.departmentSaúdepor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNINOVEpor
dc.publisher.programPrograma de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúdepor
dc.rightsAcesso Abertopor
dc.subjectfotoativaçãopor
dc.subjectresina compostapor
dc.subjectLEDpor
dc.subjectphotoactivationeng
dc.subjectcomposite resineng
dc.subjectLEDeng
dc.subject.cnpqCIENCIAS DA SAUDEpor
dc.titleEfeito de diferentes doses de energia de unidades LED uni- e multi-ondas nas propriedades mecânicas de resinas compostaspor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúde

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Ana Maria de Souza.pdfAna Maria de Souza700,75 kBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.