Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/1340
Tipo do documento: Dissertação
Título: Reprodutibilidade na avaliação da cinemática de um modelo multissegmentar do pé durante os testes de step down anterior e lateral
Título(s) alternativo(s): Repeatability in the kinematics assessment of a multi-segment foot model during anterior and lateral step down tests
Autor: Contani, Luciane Beatriz Grohs 
Primeiro orientador: Lucareli, Paulo Roberto Garcia
Primeiro coorientador: Politti, Fabiano
Primeiro membro da banca: Lucareli, Paulo Roberto Garcia
Segundo membro da banca: Yi, Liu Chiao
Terceiro membro da banca: Lanza, Fernanda de Cordoba
Resumo: Os modelos convencionais usados na análise tridimensional da marcha representavam o pé como um único segmento rígido. Desta forma, são considerados, na grande maioria dos laboratórios clínicos e de pesquisa, apenas os movimentos de flexão plantar e dorsiflexão devido a sua fragilidade para mensurar outros movimentos. Por ser o pé uma estrutura complexa, é necessário tratá-lo de maneira multissegmentar. Pesquisas recentes sobre a análise de marcha, têm utilizado o Oxford Foot Model (OFM), que trata o pé de forma segmentada. Uma vez que um modelo é proposto, o estudo de sua reprodutibilidade deve ser realizado em movimentos que ainda não foram estudados, no intuito de identificar possíveis variações entre os dados obtidos, pois os mesmos podem comprometer a interpretação dos resultados e a tomada de decisão clínica. Dessa forma, este estudo tem por objetivo avaliar a reprodutibilidade do Oxford Foot Model em adultos saudáveis durante testes funcionais, notadamente Single Leg Step Down Test Anterior (SDA) e Lateral Step Down Test (SDL), que são exercícios realizados em cadeia cinética fechada. Foi analisada a cinemática do pé de cinco adultos saudáveis (com idade de 22,2 +/- 4,7 anos) durante quatro sessões para cada um dos avaliadores (dois fisioterapeutas). Os resultados apontam alta reprodutibilidade do modelo para estes testes funcionais quando se analisa o erro padrão de medida e a amplitude de movimento articular. Foram encontradas diferenças estatisticamente significativas apenas em três comparações para a atividade SDL, o que aponta a reprodutibilidade do método. Para o SDA também foram encontradas três diferenças, concentradas nas comparações de mesmo dia. O presente estudo mostrou que o número mínimo de repetições (trials) é de três a cinco, por conterem menor erro padrão de medida; para fins estatísticos aqui elencados utilizaram-se cinco repetições.
Abstract: The aim of the present study was to analyze the Oxford Foot Model (OFM) repeatability of healthy adults during two clinical tests: the Anterior Step down Test (ASDT) and the Lateral Step down Test (LSDT). Five healthy participants (one male, four females, 10 limbs in total), with a mean age of 22.2 (±4.7) years, were assessed in four sessions of tests using an interval of one week. Two independent examiners performed two sessions of each of the tests. For each session (intra-day), nine repetitions were carried out for each clinical test (ASDT and LSDT). After an interval of three hours, the data were collected once more. The tests were conducted after an interval of a week, using the same experimental conditions. The intra and inter-session repeatability of the range of motion of the foot was determined by the standard error of measurement (SEM) of each examiner and between the examiners. Differences between the test and the retest, as well as between the examiners, were assessed using the students t-test (p<0.05). The repeatability of the data was high for the two tests conducted. The SEM results were as follows: 0.26º to 1.59º for the intra-examiner assessment (ASDT); 0.28º to 1.31º for the inter-examiner comparison (ASDT); 0.02º to 1.03º for the intra-examiner assessment (LSDT); 0.28º to 1.00º for the inter-examiner comparison (LSDT). The OFM model was shown to be reproducible in terms of assessing the range of motion during functional tests (ASDT and DAS) in healthy adults.
Palavras-chave: cinemática
reprodutibilidade
oxford foot model
testes funcionais
kinematics
repeatability
oxford foot model
functional tests
Área(s) do CNPq: CIENCIAS DA SAUDE
Idioma: por
País: Brasil
Instituição: Universidade Nove de Julho
Sigla da instituição: UNINOVE
Departamento: Saúde
Programa: Programa de Pós-Graduação em Ciências da Reabilitação
Citação: Contani, Luciane Beatriz Grohs. Reprodutibilidade na avaliação da cinemática de um modelo multissegmentar do pé durante os testes de step down anterior e lateral. 2014. 68 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo.
Tipo de acesso: Acesso Aberto
URI: http://bibliotecatede.uninove.br/handle/tede/1340
Data de defesa: 11-Dez-2014
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Reabilitação

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Luciane Beatriz Grohs Contani .pdfLuciane Beatriz Grohs Contani1,06 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.