Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://bibliotecatede.uninove.br/handle/tede/1846
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Nagano, Reny Costa dos Reis | - |
dc.contributor.advisor1 | Politti, Fabiano | - |
dc.contributor.advisor-co1 | Biasotto-Gonzalez, Daniela Aparecida | - |
dc.contributor.referee1 | Politti, Fabiano | - |
dc.contributor.referee2 | Biasotto-Gonzalez, Daniela Aparecida | - |
dc.contributor.referee3 | Amorim, Cesar Ferreira | - |
dc.date.accessioned | 2018-07-17T19:34:53Z | - |
dc.date.issued | 2016-12-13 | - |
dc.identifier.citation | Nagano, Reny Costa dos Reis. Confiabilidade teste-reteste das diferentes variáveis dinamométricas utilizadas na avaliação dos músculos do assoalho pélvico durante o ciclo menstrual. 2016. 65 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo. | por |
dc.identifier.uri | http://bibliotecatede.uninove.br/handle/tede/1846 | - |
dc.description.resumo | Introdução: incontinência urinária é definida como qualquer perda involuntária de urina que atinge mulheres adultas e que pode ser decorrente de alterações neuromusculares do assoalho pélvico. Essas alterações podem ser verificadas por meio do dinamômetro, uma vez que esse equipamento mede a força de contração proporcinada pelos músculos do assoalho pélvico (MAP). Objetivo: avaliar a confiabilidade das diferentes variáveis dinamométricas dos músculos do assoalho pélvico em mulheres saudáveis durante o ciclo menstrual. Métodos: foi avaliada a contração dos MAP de 20 mulheres com idade média de 30.85 (20-41) anos, sem queixa de perda urinária no plano sagital (ântero-posterior) e frontal (látero-lateral) por dois examinadores experientes através de um dinamômetro. As coletas foram realizadas durante três semanas consecutivas a partir do primeiro dia após o término do período menstrual. O tempo do pico (tempo em que ocorreu o pico de força a partir do início da contração dos MAP), linha base (força passiva), valor de força máxima da contração dos MAP, impulso de contração e força média da contração dos MAP, foram calculados e, a reprodutibilidade testada. O coeficiente de correlação intraclasse (ICC2,k) e o erro padrão da medida (SEM) foram usados para determinar a confiabilidade intersessão, intra e interavaliador dos valores obtidos entre três sessões de teste (teste / reteste). Resultados: na confiabilidade intra e interdias entre os avaliadores, todos os parâmetros coletados no plano sagital apresentaram excelente reprodutibilidade (ICC2,k= 0,86 até 0,98). No plano frontal, o tempo do pico e o impulso da contração apresentaram reprodutibilidade pobre e fraca intradia (ICC2,k= 0,23 e 0,59, respectivamente) e boa reprodutibilidade interdias (ICC2,k= 0,73 até 0,71, respectivamente). Os valores do SEM em geral, demonstraram que os dados coletados no plano sagital apresentam menor erro de medida em comparação aos coletados no plano frontal. Conclusão: os achados demonstraram que as alterações hormonais que acontecem durante o ciclo menstrual não influenciam a contração dos MAP. As variáveis: linha base, valor de força máxima, impulso da contração e força média da contração apresentaram excelente reprodutibilidade e podem ser utilizados de maneira segura como forma de avaliação dos MAP. | por |
dc.description.abstract | Introduction: urinary incontinence is defined as any involuntary loss of urine that affects adult women and may be due to neuromuscular changes of the pelvic floor. These changes can be verified by means of the dynamometer, since this equipment measures the contraction force proportional to the pelvic floor muscles (PFM). Aim: it`s evaluate the reliability of the different dynamometric variables of the pelvic floor muscles in healthy women during the menstrual cycle. Methods: the pelvic floor muscle (PFM) contractions of 20 women with a mean age of 30.85 (20-41) years, and no complaints of urinary loss, were evaluated in the sagittal (anteroposterior) and frontal (right-left) planes by two experienced examiners using a dynamometer. The collections were performed over three consecutive weeks from the first day after the end of the menstrual period. The peak time (PT) (time at which the peak of force occurred from the beginning of the PFM contraction), baseline (passive force), maximum PFM strength value, impulse of contraction, and average contraction force were calculated and the reproducibility tested. The intra-class correlation coefficients (ICC2,k) and the standard error of measurement (SEM) were used to determine the inter session and intra- and inter examiner reliability of the values obtained between three test sessions (test/retest). Results: For the intra and inter-day reliability between examiners all the parameters collected in the sagittal plane presented excellent reproducibility (ICC2,k= 0.86 to 0.98). In the frontal plane, the peak time and contraction impulse presented fair intra-day reproducibility (ICC2,k= 0.23 and 0.59, respectively) and good inter-day collection reproducibility (ICC2,k= 0.73 to 0.71, respectively). In general, the SEM values demonstrated that the data collected in the sagittal plane presented smaller measurement error compared to those collected in the frontal plane. Conclusions: The present findings demonstrate that the hormonal alterations that occur during the menstrual cycle do not influence the PFM contraction. The baseline, maximum strength value, impulse of contraction, and average contraction force variables presented excellent reproducibility and can be safely used as a method of PFM evaluation. | eng |
dc.description.provenance | Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-07-17T19:34:52Z No. of bitstreams: 1 Reny Costa dos Reis Nagano.pdf: 1516873 bytes, checksum: 399821fe53d9b3ed783f5811fee57787 (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2018-07-17T19:34:53Z (GMT). No. of bitstreams: 1 Reny Costa dos Reis Nagano.pdf: 1516873 bytes, checksum: 399821fe53d9b3ed783f5811fee57787 (MD5) Previous issue date: 2016-12-13 | eng |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade Nove de Julho | por |
dc.publisher.department | Saúde | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UNINOVE | por |
dc.publisher.program | Programa de Pós-Graduação em Ciências da Reabilitação | por |
dc.rights | Acesso Restrito | por |
dc.subject | fisioterapia | por |
dc.subject | assoalho pélvico | por |
dc.subject | dinamômetro | por |
dc.subject | reprodutibilidade | por |
dc.subject | confiabilidade | por |
dc.subject | physiotherapy | eng |
dc.subject | pelvic floor | eng |
dc.subject | dynamometer | eng |
dc.subject | reproducibility | eng |
dc.subject | reliability | eng |
dc.subject.cnpq | CIENCIAS DA SAUDE | por |
dc.title | Confiabilidade teste-reteste das diferentes variáveis dinamométricas utilizadas na avaliação dos músculos do assoalho pélvico durante o ciclo menstrual | por |
dc.title.alternative | Test-retest reliability of the different dynamometric variables used to evaluate pelvic floor musculature during the menstrual cycle | eng |
dc.type | Dissertação | por |
Aparece nas coleções: | Programa de Pós-Graduação em Ciências da Reabilitação |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Reny Costa dos Reis Nagano.pdf | Reny Costa dos Reis Nagano | 1,48 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar Solictar uma cópia |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.