Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/1856
Registro completo de metadados
Campo DCValorIdioma
dc.creatorCosta, Glaucio Carneiro-
dc.creator.Latteshttp://lattes.cnpq.br/1191261495586938por
dc.contributor.advisor1Corrêa, Fernanda Ishida-
dc.contributor.advisor-co1Corso, Simone Dal-
dc.contributor.referee1Corrêa, Fernanda Ishida-
dc.contributor.referee2Silva, Soraia Micaela-
dc.contributor.referee3Carvalho, Regiane Albertini de-
dc.date.accessioned2018-07-17T21:08:16Z-
dc.date.issued2016-12-13-
dc.identifier.citationCosta, Glaucio Carneiro. Validação do teste de atividade de vida diária-Glittre para avaliar a capacidade funcional de indivíduos com hemiparesia decorrente de acidente vascular encefálico. 2016. 64 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo.por
dc.identifier.urihttp://bibliotecatede.uninove.br/handle/tede/1856-
dc.description.resumoO teste de AVD Glittre (TGlittre) é um teste específico para avaliar a limitação funcional em pacientes com doença pulmonar obstrutiva crônica, porém não se sabe se pode ser utilizado para avaliar a capacidade e desempenho de pacientes pós Acidente Vascular Encefálico (AVE). Objetivos: validar o TGlittre para pacientes hemiparéticos decorrente de AVE. Métodos: a validade de construto foi analisada por meio da psicometria clássica que estabelece o emprego de métodos estatísticos bem definidos, participaram 30 adultos hemiparéticos pós AVE e 20 adultos saudáveis, pareado em gênero e idade, conforme critérios de elegibilidade. Os resultados foram correlacionados aos testes de caminhada de 6 min (TC6), time up and go (TUG) e escala de medida de independência funcional (MIF) para analisar a validade de construto. Os testes foram aleatorizados, realizados em dois dias consecutivos pelo mesmo avaliador. Os dados foram submetidos ao teste de normalidade Shapiro Wilk. O tempo de execução do teste entre os grupos foram comparados pelo teste Mann-Whitney. Resultados: houve correlação forte e significativa entre os testes AVD-Glittre versus TC6 (r=-0,91; p<0,001), TUG (r=0,82; p<0,001) e uma correlação moderada versus MIF (r=-0,47; p<0,008). Conclusões: O AVD-Glittre mostrou-se válido para avaliação da capacidade funcional e desempenho de pacientes hemiparéticos pós AVE. O teste AVD Glittre demonstra-se confiável quando correlacionado com outros testes já validados em condições de saúde distintas.por
dc.description.abstractThe Glittre AVD test (TGlittre) is a specific test to evaluate functional limitation in patients with chronic obstructive pulmonary disease, but it is not known whether it can be used to assess the capacity and performance of post-stroke patients. Objectives: To analyze the validation of TGlittre construct for hemiparetic patients due to stroke. METHODS: construct validity was analyzed using classical psychometry that established the use of well defined statistical methods, 30 hemiparetic adults after stroke and 20 healthy adults, matched in gender and age, according to eligibility criteria. The results were correlated to the 6-min walk test (TC6), time up and go (TUG) and functional independence measure scale (MIF) to analyze construct validity. The tests were randomized, performed on two consecutive days by the same evaluator. Data were submitted to the Shapiro Wilk normality test. The time of execution of the test between the groups was compared by the Mann-Whitney test. RESULTS: There was a strong and significant correlation between the AVD-Glittre versus the 6MT (r = -0.91, p <0.001), TUG (r = 0.82, p <0.001) 0.47, p <0.008). Conclusions: The AVD-Glittre was valid for evaluation of functional capacity and performance of hemiparetic patients after stroke. The Glittre AVD test is reliable when correlated with other tests already validated under different health conditions.eng
dc.description.provenanceSubmitted by Nadir Basilio (nadirsb@uninove.br) on 2018-07-17T21:08:16Z No. of bitstreams: 1 Glaucio Carneiro Costa.pdf: 1285322 bytes, checksum: 68a9e24ea8269708f461cc46ecc78e00 (MD5)eng
dc.description.provenanceMade available in DSpace on 2018-07-17T21:08:16Z (GMT). No. of bitstreams: 1 Glaucio Carneiro Costa.pdf: 1285322 bytes, checksum: 68a9e24ea8269708f461cc46ecc78e00 (MD5) Previous issue date: 2016-12-13eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Nove de Julhopor
dc.publisher.departmentSaúdepor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNINOVEpor
dc.publisher.programPrograma de Pós-Graduação em Ciências da Reabilitaçãopor
dc.rightsAcesso Abertopor
dc.subjectAVEpor
dc.subjecthemiparesiapor
dc.subjectcapacidade funcionalpor
dc.subjectGlittrepor
dc.subjectvalidaçãopor
dc.subjectstrokeeng
dc.subjecthemiparesiseng
dc.subjectfunctional abilityeng
dc.subjectGlittreeng
dc.subjectvalidationeng
dc.subject.cnpqCIENCIAS DA SAUDEpor
dc.titleValidação do teste de atividade de vida diária-Glittre para avaliar a capacidade funcional de indivíduos com hemiparesia decorrente de acidente vascular encefálicopor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Reabilitação

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Glaucio Carneiro Costa.pdfGlaucio Carneiro Costa1,26 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.