Compartilhamento |
![]() ![]() |
Use este identificador para citar ou linkar para este item:
http://bibliotecatede.uninove.br/handle/tede/2305
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Gomes, Bianca Tiriba | - |
dc.creator.Lattes | http://lattes.cnpq.br/2269906625299506 | por |
dc.contributor.advisor1 | Corrêa, Fernanda Ishida | - |
dc.contributor.advisor-co1 | Corso, Simone Dal | - |
dc.contributor.referee1 | Corrêa, Fernanda Ishida | - |
dc.contributor.referee2 | Dias, Raphael Mendes Ritti | - |
dc.contributor.referee3 | Pompeu, José Eduardo | - |
dc.date.accessioned | 2020-10-28T18:38:25Z | - |
dc.date.issued | 2019-12-10 | - |
dc.identifier.citation | Gomes, Bianca Tiriba. Validação e reprodutibilidade do teste de atividade de vida diária-Glittre para avaliar a capacidade funcional de idosos. 2019. 53 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo. | por |
dc.identifier.uri | http://bibliotecatede.uninove.br/handle/tede/2305 | - |
dc.description.resumo | Introdução: O Teste de Atividade da Vida Diária Glittre (AVD-Glittre) mostrou-se um instrumento completo para avaliar o desempenho funcional, porém, ainda não foi verificado em idosos saudáveis. Objetivo: Verificar se o AVD-GLITTRE é válido para avaliar a capacidade funcional (CF) de idosos, analisar a reprodutibilidade inter e intra-avaliador e comparar o desempenho do teste com diferentes classificações quanto ao nível de aptidão física (AF) dos idosos. Metodologia: Estudo transversal com amostra composta por 100 idosos, 68,16±5,16 anos, de ambos os sexos. A validade de construto AVD-Glittre foi realizada pela sua correlação com o teste de caminhada de 6 minutos (TC6) e o Timed up and Go Test (TUG), de acordo com o melhor resultado do teste de cada paciente. A reprodutibilidade intra-avaliador foi realizada pelo avaliador 1, no mesmo dia, com intervalo de 30 minutos e a reprodutibilidade inter-avaliador foi realizada pelo avaliador 2, com intervalo mínimo de 24 horas e máximo de 7 dias. Resultados: Houve correlação entre o tempo do AVD-Glittre com o TC6 (r=-0,76; p<0,001) e o TUG (r=0,77; p<0,001). A confiabilidade intra-avalidor (coeficiente de correlação intraclasse, CCI = 0,90 e intervalo de confiança de 95%, IC95% = 0,86-0,93; p<0,001) e inter-avaliador (CCI=0,91; IC95%: 0,88-0,94; p<0,001). O Erro Padrão de Medida intra-avaliador foi de 0,03 min e inter- avaliador 0,05 min. A Mínima Mudança Detectável intra-avaliador foi de 0,40 min e inter-avaliador 0,07 min. Quanto a comparação do nível de AF e o AVD-Glittre não houve significância (U=973,500; p>0,28). Conclusão: O AVD-Glittre mostrou-se válido e reprodutível para avaliar a CF de idosos. Não houve significância entre o nível de AF e o desempenho no tempo do AVD-Glittre. | por |
dc.description.abstract | Introduction: The Glittre-Activity Daily Living (Glittre-ADL) Test showed to be a complete tool to evaluate the functional development; however, it has not yet been investigated in the healthy elderly population. Objective: To verify whether the Glittre-ADL is valid for evaluating the functional capacity (FC) in the elderly, to analyse the inter-rater and intra-rater reproducibility and to compare the test performance with different classifications regarding the level of physical fitness (PF) in the elderly. Methodology: A cross-transversal study composed of 100 elderly, 68,16±5,16 years, both sexes. The construct validity of the Glittre-ADL test was made by its correlation with the six-minute walk distance (6MWD) and the Timed up and Go Test (TUG) according to the best result of each patient. The intra-rater reproducibility was made by the rater 1 on the same day with an interval of 30 minutes and the inter-rater reproducibility was done by the rater 2, with a minimal interval of 24 hours and a maximum interval of 7 days. Results: There was a correlation between the Glittre-ADL test time with the 6MWD (r=-0,76; p<0,001) and the TUG (r=0,77; p<0,001). The intra-rater reliability (intraclass correlation coefficient, ICC = 0,90 and the confidence interval (CI) 95%, CI95% = 0,86-0,93; p<0,001) and the inter-rater (ICC=0,91; CI95%: 0,88-0,94; p<0,001). The Standard Error of Measurement (SEM) intra-rater was 0,03 min and inter-rater 0,05 min. The Minimal Detectable Change (MDC) intra-rater was 0,40 min and inter-rater 0,07 min. There was no significance (U=973,500; p>0,28) as for the comparison level of PF and the Glitter-ADL. Conclusion: The Glittre-ADL proved to be valid and reproducible to evaluate the FC in the elderly. There was no significance between PF level and time performance of ADL-Glittre test. | eng |
dc.description.provenance | Submitted by Nadir Basilio (nadirsb@uninove.br) on 2020-10-28T18:38:25Z No. of bitstreams: 1 BIANCA TIRIBA GOMES.pdf: 952293 bytes, checksum: 306298c70ce8ab6d5e19cfe1ef3d33ba (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2020-10-28T18:38:25Z (GMT). No. of bitstreams: 1 BIANCA TIRIBA GOMES.pdf: 952293 bytes, checksum: 306298c70ce8ab6d5e19cfe1ef3d33ba (MD5) Previous issue date: 2019-12-10 | eng |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade Nove de Julho | por |
dc.publisher.department | Saúde | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UNINOVE | por |
dc.publisher.program | Programa de Pós-Graduação em Ciências da Reabilitação | por |
dc.rights | Acesso Restrito | por |
dc.subject | envelhecimento | por |
dc.subject | qualidade de vida | por |
dc.subject | atividades cotidianas | por |
dc.subject | AVD-Glittre | por |
dc.subject | desempenho físico funcional | por |
dc.subject | estudos de validação | por |
dc.subject | reprodutibilidade dos testes | por |
dc.subject | aging | eng |
dc.subject | quality of life | eng |
dc.subject | daily activities | eng |
dc.subject | Glittre-ADL test (GT) | eng |
dc.subject | functional physical performance | eng |
dc.subject | validation studies | eng |
dc.subject | reproducibility of tests | eng |
dc.subject.cnpq | CIENCIAS DA SAUDE | por |
dc.title | Validação e reprodutibilidade do teste de atividade de vida diária-Glittre para avaliar a capacidade funcional de idosos | por |
dc.title.alternative | Validation and reproducibility of the test | eng |
dc.type | Dissertação | por |
Aparece nas coleções: | Programa de Pós-Graduação em Ciências da Reabilitação |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
BIANCA TIRIBA GOMES.pdf | BIANCA TIRIBA GOMES | 929,97 kB | Adobe PDF | Baixar/Abrir Pré-Visualizar Solictar uma cópia |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.