Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/2661
Registro completo de metadados
Campo DCValorIdioma
dc.creatorTraverzim, Maria Aparecida dos Santos-
dc.creator.Latteshttp://lattes.cnpq.br/7995146756619559por
dc.contributor.advisor1Motta, Lara Jansiski-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/6750462252900819por
dc.contributor.referee1Motta, Lara Jansiski-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/6750462252900819por
dc.contributor.referee2Horliana, Anna Carolina Ratto Tempestini-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/0442315483134442por
dc.contributor.referee3Bussadori, Sandra Kalil-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/4110914499694913por
dc.contributor.referee4Navarro, Ricardo Scarparo-
dc.contributor.referee4Latteshttp://lattes.cnpq.br/9120674464635588por
dc.contributor.referee5Cernach, Marlene Cecilia Soares Pinho-
dc.date.accessioned2021-11-04T15:56:52Z-
dc.date.issued2019-07-26-
dc.identifier.citationTraverzim, Maria Aparecida dos Santos. Análise do efeito da biofotomodulação na analgesia durante o trabalho de parto: ensaio clínico controlado. 2019. 70 f. Tese( Programa de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúde) - Universidade Nove de Julho, São Paulo.por
dc.identifier.urihttp://bibliotecatede.uninove.br/handle/tede/2661-
dc.description.resumodor durante o trabalho de parto pode ser considerada um empecilho para a escolha pelo parto vaginal. Na tentativa de amenizar o quadro de dor durante o trabalho de parto vários métodos farmacológicos e não farmacológicos são propostos. Na busca de alternativas ao tratamento farmacológico para a analgesia durante o trabalho de parto e que sejam efetivas e para serem utilizadas tanto em instituições públicas quanto privadas, esta pesquisa tem o objetivo de avaliar o efeito da fotobiomodulação com LED (Light Emitting Diode) na analgesia durante o trabalho de parto. Para tanto, realizou-se um ensaio clínico com 29 mulheres divididas em dois grupos: G1 (grupo experimental-LED) e G2 (Grupo controle - banho quente). No grupo experimental a placa de LED (vermelho e infravermelho) foi colocada na região dorsal da paciente, a nível de T10 a S4, por 10 minutos, sendo que a placa se desligava automaticamente.O banho quente em temperatura controlada foi realizado durante 30 minutos. Para verificar o efeito do LED na analgesia durante o trabalho de parto, foram avaliadas as seguintes variáveis: (1) percepção da dor; (2) condições fetais utilizando cardiotocografia ou ausculta fetal intermitente; (3) índice de Apgar no primeiro e quinto minutos após o nascimento e (4) tempo de parto. Observou-se diferença estatisticamente significante (p<0,05) na redução da dor, por meio de escala visual milimetrada antes e depois da aplicação no G1 - LED (7,92+- 1,78). Em relação às outras variáveis, não houve diferença estatisticamente entre os grupos ao comparar as condições fetais, índice de Apgar e tempo de parto. Conclui-se que o LED pode ser considerado uma alternativa, uma vez que apresentou como efeito a redução da dor sem alterações nos demais parâmetros durante o trabalho de parto ao comparar com o método do banho quente utilizado como protocolo nos hospitais, demonstrando-se seguro. Sugere-se, no entanto, continuidade nos ensaios clínicos com maior amostra e possíveis ajustes dosimétricos para estabelecimento de um protocolo de fotobiomodulação para analgesia durante o parto.por
dc.description.abstractPain during labor may be considered as an impediment for choosing a vaginal delivery. In an attempt to reduce pain during labor, several pharmacological and non-pharmacological methods are proposed. In the search for alternatives to pharmacological treatment for analgesia during labor wich are effective and to be used in both public and private institutions, this research has the objective of evaluating the effect of photobiomodulation with LED (Light Emitting Diode) in analgesia during labor. For this, a clinical trial was performed with 29 women divided into two groups: G1 (experimental group-LED) and G2 (Control group - hot bath). In the experimental group, the LED plate (red and infrared) was placed in the dorsal region of the patient from T10 to S4 level for 10 minutes, and the plate switched off automatically. The hot temperature controlled bath was performed for 30 minutes. To verify the effect of LED on analgesia during labor, the following variables were evaluated: (1) perception of pain; (2) fetal conditions using cardiotocography or intermittent fetal auscultation; (3) Apgar score in the first and fifth minutes after birth and (4) time of delivery. A statistically significant difference (p <0.05) in pain reduction was observed by means visual scale before and after application in G1 - LED (7.92 + - 1.78). Regarding the other variables, there was no statistically significant difference between the groups when comparing fetal conditions, Apgar score and delivery time. It is concluded that the LED can be considered an alternative, since it had as effect the reduction of the pain without changes in the other parameters during labor when comparing with the hot bath method used as protocol in the hospitals, demonstrating to be safe. It is suggested, however, the continuity in the clinical trials with larger samples and possible dosimetric adjustments to establish a photobiomodulation protocol for analgesia during childbirth.eng
dc.description.provenanceSubmitted by Nadir Basilio (nadirsb@uninove.br) on 2021-11-04T15:56:52Z No. of bitstreams: 1 Maria Aparecida dos Santos Traverzim.pdf: 1731420 bytes, checksum: e84e14cd85ebfb2121f0b299796903d1 (MD5)eng
dc.description.provenanceMade available in DSpace on 2021-11-04T15:56:52Z (GMT). No. of bitstreams: 1 Maria Aparecida dos Santos Traverzim.pdf: 1731420 bytes, checksum: e84e14cd85ebfb2121f0b299796903d1 (MD5) Previous issue date: 2019-07-26eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Nove de Julhopor
dc.publisher.departmentSaúdepor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNINOVEpor
dc.publisher.programPrograma de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúdepor
dc.rightsAcesso Abertopor
dc.subjectanalgesiapor
dc.subjecttrabalho de partopor
dc.subjectlight emitter diodepor
dc.subjectdorpor
dc.subjectbiofotomodulaçãopor
dc.subjectanalgesiaeng
dc.subjectlaboreng
dc.subjectlight emitter diodeeng
dc.subjectpaineng
dc.subjectbiophotomodulationeng
dc.subject.cnpqCIENCIAS DA SAUDEpor
dc.titleAnálise do efeito da biofotomodulação na analgesia durante o trabalho de parto: ensaio clínico controladopor
dc.title.alternativeAnalysis of the effect of biophotomodulation on analgesia during labor: a controlled clinical testeng
dc.typeTesepor
Aparece nas coleções:Programa de Pós-Graduação em Biofotônica Aplicada às Ciências da Saúde

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Maria Aparecida dos Santos Traverzim.pdfMaria Aparecida dos Santos Traverzim1,69 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.