| Título: | Confiabilidade teste-reteste de um protocolo de coleta do sinal eletromiográfico do músculo masseter em indivíduos com disfunção temporomandibular |
| Título(s) alternativo(s): | Test-retest reliability of a protocol for collecting the electromyographic signal from the masseter muscle in temporomandibular disorders patients |
| Autor: | Nakamura, Cindy Mozer ![]() |
| Primeiro orientador: | Politti, Fabiano |
| Primeiro coorientador: | Biasotto-Gonzalez, Daniela Aparecida |
| Primeiro membro da banca: | Politti, Fabiano |
| Segundo membro da banca: | Gomes, Cid André Fidelis de Paula |
| Terceiro membro da banca: | Carvalho, Leandro Silva de |
| Resumo: | Introdução: A disfunção temporomandibular (DTM) é uma condição dolorosa comum na articulação temporomandibular e de músculos associados que pode afetar de 11% a 34%. Portanto, é importante determinar a variação nas medidas de eletromiografia (EMG) antes de propor um protocolo de coleta do sinal EMG para avaliar a eficácia das terapias administradas para melhorar a função dos músculos mastigatórios nesta população. Objetivos: Verificar a confiabilidade teste-reteste de um protocolo de coleta do sinal eletromiográfico do músculo masseter em indivíduos com DTM. Métodos: Esse foi um estudo transversal composto por 20 indivíduos com DTM e idade entre 18 e 50 anos. O sinal EMG do músculo masseter foi coletado em duas sessões de testes (teste e reteste) com intervalo de 7 dias entre as coletas em duas condições: máxima intercuspidação habitual (MIH) e Isotonia (ISOT- mastigação). Para cada condição de teste, foram realizadas 3 gravações do sinal EMG, sendo esse avaliado pelas variáveis integral (iEMG) e a raiz quadrada da média do sinal (RMS). A confiabilidade relativa e a absoluta foram avaliadas utilizando o coeficiente de correlação intraclasse (ICC2,k e ICC2,1) e o erro padrão de medida (SEM) respectivamente. Resultados: Na análise intradia o ICC foi considerado excelente para os valores verificados pelas variáveis RMS (ICC= 0.85 a 0.96) e iEMG (ICC= 0.85 a 0.95) em ambos os músculos sendo que a primeira sessão de testes (teste) apresentou maior intervalo do SEM (SEM=3.09 a 7.59) em relação à segunda sessão de testes (reteste) (SEM=3.64 a 6.77). Em relação à confiabilidade interdias em ambas as condições de testes (MHI e ISOT), os ICCs revelaram confiabilidade pobre para as variáveis RMS (ICC2,1= 0.03 a 0.29) e iEMG (ICC2,1= 0.08 a 0.39) sendo o SEM considerado alto para essas medidas (SEM= 11.98 a 17.65). Conclusões: O protocolo de coleta do sinal EMG do músculo masseter em indivíduos com DTM demonstrou que os dados são confiáveis somente na mesma sessão de coletas enquanto que, para coletas em dias alternados a confiabilidade foi pobre. |
| Abstract: | Introduction: Temporomandibular disorder (TMD) is a common painful condition on the temporomandibular joint and associated muscles that can affect from 11% to 34%. Therefore, it is important to determine the variation in electromyography (EMG) measurements before proposing an EMG signal recording protocol to assess the effectiveness of therapies administered to improve masticatory muscle function in this population. Objectives: To verify the test-retest reliability of a protocol for collecting the electromyographic signal from the masseter muscle in TMD patients. Methods:A cross-sectional study comprising 20 individuals with TMD aged between 18 and 50 years. The EMG signal of the masseter muscle was collected in two test sessions (test and retest) with an interval of 7 days between collections in two conditions: maximum habitual intercuspation (MIH) and Isotonia (ISOT-chewing). For each test condition, 3 recordings of the EMG signal were performed, which was evaluated by the variables integral (iEMG) and the root mean square of the signal (RMS). Relative and absolute reliability were evaluated using the intraclass correlation coefficient (ICC2,k and ICC2,1) and the measurement standard error (SEM) respectively. Results: Intraday analysis, the ICC was considered excellent for the values verified by the RMS variables (ICC= 0.85 to 0.96) and iEMG (ICC= 0.85 to 0.95) in both muscles, with the first test session (test) presenting a greater interval of SEM (SEM=3.09 to 7.59) in relation to the second test session (retest) (SEM=3.64 to 6.77). Regarding the interday reliability in both test conditions (MHI and ISOT), the ICCs revealed poor reliability for the variables RMS (ICC2.1= 0.03 to 0.29) and iEMG (ICC2.1= 0.08 to 0.39) being the SEM considered high for these measures (SEM= 11.98 to 17.65). Conclusions: The protocol for collecting the EMG signal from the masseter muscle in individuals with TMD demonstrated that the data are reproducible only in the same collection session, while for collections on alternate days, the reliability was poor. |
| Palavras-chave: | disfunção temporomandibular reprodutibilidade confiabilidade eletromiografia músculo masseter temporomandibular disorders reproducibility reliability electromyography masseter muscle |
| Área(s) do CNPq: | CIENCIAS DA SAUDE |
| Idioma: | por |
| País: | Brasil |
| Instituição: | Universidade Nove de Julho |
| Sigla da instituição: | UNINOVE |
| Departamento: | Saúde |
| Programa: | Programa de Pós-Graduação em Ciências da Reabilitação |
| Citação: | Nakamura, Cindy Mozer. Confiabilidade teste-reteste de um protocolo de coleta do sinal eletromiográfico do músculo masseter em indivíduos com disfunção temporomandibular. 2022. 38 f. Dissertação( Programa de Pós-Graduação em Ciências da Reabilitação) - Universidade Nove de Julho, São Paulo. |
| Tipo de acesso: | Acesso Aberto |
| URI: | http://bibliotecatede.uninove.br/handle/tede/3533 |
| Data de defesa: | 19-Dez-2022 |
| Aparece nas coleções: | Programa de Pós-Graduação em Ciências da Reabilitação |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| Cindy Mozer Nakamura.pdf | Cindy Mozer Nakamura | 665,48 kB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.