| Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://bibliotecatede.uninove.br/handle/tede/3925Registro completo de metadados
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.creator | Mazzoni, Adriana Cátia | - |
| dc.creator.Lattes | http://lattes.cnpq.br/9684070586659649 | por |
| dc.contributor.advisor1 | Motta, Lara Jansiski | - |
| dc.contributor.advisor1Lattes | http://lattes.cnpq.br/6750462252900819 | por |
| dc.contributor.referee1 | Motta, Lara Jansiski | - |
| dc.contributor.referee1Lattes | http://lattes.cnpq.br/6750462252900819 | por |
| dc.contributor.referee2 | Bussadori, Sandra Kalil | - |
| dc.contributor.referee2Lattes | http://lattes.cnpq.br/4110914499694913 | por |
| dc.contributor.referee3 | Prates, Renato Araujo | - |
| dc.contributor.referee3Lattes | http://lattes.cnpq.br/7664790931310514 | por |
| dc.contributor.referee4 | Navarro, Ricardo Scarparo | - |
| dc.contributor.referee4Lattes | http://lattes.cnpq.br/9120674464635588 | por |
| dc.contributor.referee5 | Sobral, Ana Paula Taboada | - |
| dc.contributor.referee5Lattes | http://lattes.cnpq.br/6455262799298077 | por |
| dc.date.accessioned | 2026-03-23T17:37:27Z | - |
| dc.date.issued | 2025-12-10 | - |
| dc.identifier.citation | Mazzoni, Adriana Cátia. Avaliação térmica e histológica da incisão cirúrgica no freio lingual com lasers de diodo (450 nm e 980 nm) em modelo animal (ratos wistar). 2025. 69 f. Tese( Programa de Pós-Graduação em Medicina – Biofotônica) - Universidade Nove de Julho, São Paulo. | por |
| dc.identifier.uri | http://bibliotecatede.uninove.br/handle/tede/3925 | - |
| dc.description.resumo | Os instrumentos cirúrgicos térmicos são amplamente utilizados em cirurgias de tecidos moles pela capacidade de promover hemostasia e reduzir a necessidade de suturas, sendo indicados também para a liberação do freio lingual. Entretanto, os efeitos do aquecimento sobre o tecido e o reparo tecidual local ainda suscitam questionamentos. Este estudo, em duas etapas, teve como objetivo avaliar os efeitos térmicos e o reparo tecidual após incisões relizadas no freio lingual com diferentes instrumentos. Na primeira etapa, ex vivo, 60 línguas suínas foram submetidas a incisões com tesoura Íris, eletrocautério, bisturi eletrônico, laser de érbio (em diferentes parâmetros) e lasers de diodo de alta potência (450 nm e 980 nm, com diferentes parâmetros). A temperatura foi monitorada por termografia infravermelha (FLIR C5) registrando valores durante, ao final e 1 minuto após as incisões. Observou-se menor aquecimento no grupo tesoura (5,6 °C) e maiores médias no laser de diodo de alta potência 980 nm (22,6 °C) e no 450 nm (16,7 °C), sendo que o último apresentou o resfriamento mais rápido (13,6 °C em 1 minuto). Na segunda etapa, a escolha dos instrumentos foi realizada de acordo com os resultados da primeira etapa. Foram escolhidos dois instrumentos de laser de diodo de alta potência no modo pulsado, que apresentavam o mesmo tipo de ponta na fibra, com 600 micrometros de diâmetro, mas com comprimentos de onda diferentes. Esta etapa foi conduzida in vivo com 30 ratos Wistar jovens que se encontravam na faixa etária antes da puberdade, distribuídos em três grupos: tesoura (controle), laser de diodo 450 nm e laser de diodo 980 nm, ambos no modo pulsado. Foram realizadas análises termográficas e histológicas nos períodos imediato e pós-operatório (dias 0 e 7). O laser diodo 980 nm apresentou um caso de sangramento controlado durante o procedimento, enquanto o grupo laser diodo de 450 nm não apresentou nenhum caso de qualquer sangramento, entretanto, apesar de apresentarem resultado de reparação tecidual clínico semelhantes, no sétimo dia; o grupo laser 450 nm, apresentou menor quantidade de feixes de colágeno desorganizados com aspecto fibrosado em relação ao uso do laser 980 nm, e mais semelhante ao uso da tesoura cirúrgica. Ambos os instrumentos térmicos apresentaram características clínicas, térmicas e histológicas semelhantes e podem ser empregados de forma segura para incisões na região do freio lingual apresentando padrões semelhantes de aquecimento e de reparo tecidual. Espera-se que os resultados auxiliem na compreensão da segurança térmica e biológica desses lasers em cirurgia do freio lingual, entretanto é necessário mais estudos histológicos e clínicos que confirmem estes achados. | por |
| dc.description.abstract | Thermal surgical instruments are widely used in soft tissue surgeries due to their ability to promote hemostasis and reduce the need for sutures; they are also indicated for lingual frenectomy. However, the effects of heating on the tissue and local tissue repair still raise questions. This two-stage study aimed to evaluate the thermal effects and tissue repair after incisions performed on the lingual frenulum using different instruments. In the first stage (ex vivo), 60 porcine tongues underwent incisions with Iris scissors, electrocautery, electronic scalpel, erbium laser (at different parameters), and high-power diode lasers (450 nm and 980 nm, at different parameters). Temperature was monitored via infrared thermography (FLIR C5), recording values during, at the end of, and 1 minute after the incisions. The lowest heating was observed in the scissors group (5.6 °C), while the highest averages were found in the 980 nm high-power diode laser (22.6 °C) and the 450 nm laser (16.7 °C); the latter showed the fastest cooling (13.6 °C within 1 minute). In the second stage, the instruments were selected based on the results of the first stage. Two high-power diode laser instruments in pulsed mode were chosen, featuring the same fiber tip type (600 micrometers diameter) but different wavelengths. This stage was conducted in vivo with 30 young pre-pubescent Wistar rats, distributed into three groups: scissors (control), 450 nm diode laser, and 980 nm diode laser, both in pulsed mode. Thermographic and histological analyses were performed in the immediate and postoperative periods (days 0 and 7). The 980 nm diode laser group presented one case of controlled bleeding during the procedure, while the 450 nm diode laser group presented no cases of bleeding. Although both showed similar clinical tissue repair results on the seventh day, the 450 nm laser group exhibited a smaller amount of disorganized, fibrotic-like collagen bundles compared to the 980 nm laser, appearing more similar to the surgical scissors group. Both thermal instruments presented similar clinical, thermal, and histological characteristics and can be safely employed for lingual frenulum incisions, showing similar heating and tissue repair patterns. It is expected that these results will aid in understanding the thermal and biological safety of these lasers in lingual frenulum surgery; however, further histological and clinical studies are necessary to confirm these findings. | eng |
| dc.description.provenance | Submitted by Nadir Basilio (nadirsb@uninove.br) on 2026-03-23T17:37:27Z No. of bitstreams: 1 Adriana Cátia Mazzoni .pdf: 2165755 bytes, checksum: 01eb1079ffd0bc554e294052367b6c57 (MD5) | eng |
| dc.description.provenance | Made available in DSpace on 2026-03-23T17:37:27Z (GMT). No. of bitstreams: 1 Adriana Cátia Mazzoni .pdf: 2165755 bytes, checksum: 01eb1079ffd0bc554e294052367b6c57 (MD5) Previous issue date: 2025-12-10 | eng |
| dc.format | application/pdf | * |
| dc.language | por | por |
| dc.publisher | Universidade Nove de Julho | por |
| dc.publisher.department | Saúde | por |
| dc.publisher.country | Brasil | por |
| dc.publisher.initials | UNINOVE | por |
| dc.publisher.program | Programa de Pós-Graduação em Medicina – Biofotônica | por |
| dc.rights | Acesso Aberto | por |
| dc.subject | laser de alta potência | por |
| dc.subject | freio lingual | por |
| dc.subject | termografia | por |
| dc.subject | frenectomia | por |
| dc.subject | infiltrado inflamatório | por |
| dc.subject | high-power laser | eng |
| dc.subject | lingual frenulum | eng |
| dc.subject | thermography | eng |
| dc.subject | frenectomy | eng |
| dc.subject | inflammatory infiltrate | eng |
| dc.subject.cnpq | CIENCIAS DA SAUDE | por |
| dc.title | Avaliação térmica e histológica da incisão cirúrgica no freio lingual com lasers de diodo (450 nm e 980 nm) em modelo animal (ratos wistar) | por |
| dc.title.alternative | Thermal and histological assessment of lingual frenum surgical incision using diode lasers (450 nm and 980 nm) in an animal model (wistar rats) | eng |
| dc.type | Tese | por |
| Aparece nas coleções: | Programa de Pós-Graduação em Medicina – Biofotônica | |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| Adriana Cátia Mazzoni .pdf | Adriana Cátia Mazzoni | 2,11 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.
