Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bibliotecatede.uninove.br/handle/tede/862
Registro completo de metadados
Campo DCValorIdioma
dc.creatorFonseca, Letícia Alves-
dc.contributor.advisor1Oliveira, Claudia Santos-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/8012781178161885por
dc.contributor.advisor-co1Corrêa, João Carlos Ferrari-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/7430706253523346por
dc.contributor.referee1Biasotto-Gonzalez, Daniela Aparecida-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/6741738316587978por
dc.contributor.referee2Sá, Cristina dos Santos Cardoso de-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/9259523998158401por
dc.date.accessioned2015-04-22T17:20:34Z-
dc.date.available2012-06-21-
dc.date.issued2011-12-13-
dc.identifier.citationFONSECA, Letícia Alves. Used portable device for evaluation of the hipertonia of the joint of the ankle in individuals with cerebral paralysis. 2011. 127 f. Dissertação (Mestrado em Saúde) - Universidade Nove de Julho, São Paulo, 2011.por
dc.identifier.urihttp://bibliotecatede.uninove.br/tede/handle/tede/862-
dc.description.resumoO objetivo geral do estudo foi avaliar a aplicabilidade de um dispositivo portátil na mensuração da hipertonia da articulação do tornozelo em indivíduos com paralisia cerebral do tipo espástica. Foram triados inicialmente 42 indivíduos da clínica escola da UNINOVE. Após avaliação em conformidade com critérios de inclusão e exclusão, foi selecionada uma amostra de 28 indivíduos, sendo que para o primeiro estudo foram incluídos 14 indivíduos (8,5 ± 0,7 anos) classificados segundo o GMFCS em nível I, II e III e, para o segundo estudo, foram incluídos 17 indivíduos (9,6 ± 2,3 anos). Trata-se de um estudo observacional, tranversal e não controlado. A amostra dos dois estudos foi caracterizada como amostra de conveniência. Primeiramente, foi utilizada a escala de equilíbrio de Berg para a avaliação do equilíbrio funcional e o GMFM-66 para mensuração da função motora grossa. O equilíbrio funcional apresentou correlação positiva com a função motora grossa referente às atividades de engatinhar e ajoelhar, permanecer em pé, andar, correr e pular, propostas pelo GMFM-66 (p<0,01). Posteriormente, foi avaliada a hipertonia destes indivíduos por meio da escala modificada de Ashworth(EMA) e do dispositivo portátil desenvolvido pelo Instituto Politécnico de Milão. A EMA e o dispositivo desenvolvido para mensurar hipertonia apresentaram alta correlação negativa, ou seja, quanto maior o grau de hipertonia de um indivíduo avaliado pela EMA menor a relação ângulo-momento encontrada pelo dispositivo, o que vai de acordo com a literatura pesquisada. A EMA e o dispositivo desenvolvido apresentaram o mesmo comportamento na avaliação da hipertonia do tornozelo em indivíduos com paralisia cerebral, sugerindo-se, assim que o dispositivo portátil pode ser utilizado como um recurso a mais para avaliação destes indivíduos na prática clínica.por
dc.description.abstractThe aim of the present study was to evaluate the applicability of a portable device for measuring hypertonia of the ankle joint in subjects with spastic cerebral palsy. An uncontrolled, observational, cross-sectional study was carried out with convenience sample. For such, 42 individuals were initially screened at the UNINOVE clinic school (Brazil). After application of the inclusion and exclusion criteria, 28 individual were selected and classified according to GMFCS levels I,II AND III; 14 subjects (8.5 ± 0.7 years) were included in the first study and 17 subjects (9.6 ± 2.3 years) were included in the second study. Functionality was evaluated using the Berg balance scale for the assessment of functional balance and GMFM-66 to measure gross motor function. Functional balance was positively correlated with the gross motor function on the activities of crawling, kneeling, standing, walking, running and jumping, as proposed by the GMFM-66 (p < 0.01). Hypertonia was then assessed the modified Ashworth scale(MAS) and a portable device developed by the Polytechnic Institute of Milan. The MAS and portable device exhibited a highly negative correlation, a greater degree of hypertonia determined by MAS which is in agreement with findings reported in the literature. The MAS and portable device exhibited the same behavior in the evaluation of ankle hypertonia in individuals with cerebral palsy, suggesting that portable device may be used as additional resource for the evaluation of these individuals in clinical practice.eng
dc.description.provenanceMade available in DSpace on 2015-04-22T17:20:34Z (GMT). No. of bitstreams: 1 B_Leticia Alves Fonseca.pdf: 8430879 bytes, checksum: c2dd7f1cf1474c4fffafc21096ba8c31 (MD5) Previous issue date: 2011-12-13eng
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Nove de Julhopor
dc.publisher.departmentSaúdepor
dc.publisher.countryBRpor
dc.publisher.initialsUNINOVEpor
dc.publisher.programPrograma de Pós-Graduação em Ciências da Reabilitaçãopor
dc.rightsAcesso Abertopor
dc.subjecthipertonia muscularpor
dc.subjectparalisia cerebralpor
dc.subjectarticulação do tornozelopor
dc.subjectmuscle hypertoniaeng
dc.subjectcerebral palsyeng
dc.subjectankle jointeng
dc.subject.cnpqCIENCIAS DA SAUDEpor
dc.titleDispositivo portátil utilizado para avaliação da hipertonia da articulação do tornozelo em indivíduos com paralisia cerebralpor
dc.title.alternativeUsed portable device for evaluation of the hipertonia of the joint of the ankle in individuals with cerebral paralysiseng
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Ciências da Reabilitação

Arquivos associados a este item:
Arquivo TamanhoFormato 
B_Leticia Alves Fonseca.pdf8,23 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.